**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹
如果您對該產(chǎn)品感興趣的話(huà),可以
產(chǎn)品名稱(chēng): **供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹
產(chǎn)品型號: LFR-1-D-MAXI-A-MPA
產(chǎn)品展商: FESTO
產(chǎn)品文檔: 無(wú)相關(guān)文檔
簡(jiǎn)單介紹
**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹
?visualising the signals and parameters, and can thus be used as a remote display for transmitters.
The switching outputs can be configured to monitor a threshold value, signal range or signal change.
The outputs can be set as PNP or NPN and normally open (NO) or normally closed (NC).
Process values can be read out and parameters changed and
**供應德國費斯托信號轉換器,FESTO轉換
**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹
的詳細介紹
**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹
上海乾拓貿易有限公司
企業(yè)QQ:
電話(huà);021-69001039
手機;17321017802(微信)
郵箱;17321017802@163.com
地址:上海市嘉定區江橋嘉涌路99弄6號713室
visualising the signals and parameters, and can thus be used as a remote display for transmitters.
The switching outputs can be configured to monitor a threshold value, signal range or signal change.
The outputs can be set as PNP or NPN and normally open (NO) or normally closed (NC).
Process values can be read out and parameters changed and transmitted to additional devices via the IO-Link® interface.
Converts analogue signals into digital switching signals Conversion of analogue signals in IO-Link®
Reduction in analogue signals to the control systems
inchHg inchH2O kgf/cm2 l/min l/h scfm scfh GPM mm inch V MA %
Flexible use Transmitter signal area scalable (e.g.: 1 … 5 V)
Pressure transmitters SPTE, SDE5-NF-V, SPTW Vacuum generator OVEL with SPTE
Flow transmitters SFET-F, SFET-R Position sensors SDAT, SMAT-8E, SMAT-8M
Analogue sensor box SRAP Inductive sensors with analogue output SIEA
Certification RCM compliance mark CE marking (see declaration of conformity)
In accordance with EU EMC Directive Ambient temperature [°C] 0 … +50 Note on materials RoHS compliant
Input signal –2V –2A
Measured variable Voltage Current Signal range [V] 0 … 10 – [mA] – 0 … 20 Sampling interval [ms] 1
Output, general
Accuracy FS [%] 0.5 Repetition accuracy [%] 0.2
Switching output
Switching output 2 x PNP or 2 x NPN, switchable Switching function Freely programmable Switching
element function N/C or N/O contact, switchable Max. output current [mA] 100 Short circuit protection Yes
Operating voltage range DC [V] 15 … 30 Reverse polarity protection For all electrical connections
Electrical connection, input Function Analogue input, power supply Connection type 2x socket
Connection technology Plug pattern EC Number of pins/wires 4
Electrical connection, output Function Power supply, communication, switching output
Easy operation Blue display with high-contrast white text and red switchover
Intuitive menu navigation, as for pressure sensors SPAU and SPAN
Communication interface
Many integrated functions Min./max. monitoring PNP/NPN, switchable
Eco mode Tamper protection with security code Filter can be adjusted to smooth the signals
The switching points can be easily set via teach-in Parameters can be easily copied to other devices
Values can be displayed in many units bar kPa MPa psi mmHg
Measured value indicator can be individually configured Lots of integrated switching functions
Product description Area of application
The signal converter detects analogue current or voltage signals from sensors (transmitters).
Connection to the higher-level system is provided by 1 or 2 switching outputs
or alternatively by an IO-Link® interface. The signal converter has a display for
Connection type Plug connector Connection technology Plug pattern L1J Number of pins/wires 4
IO-Link® device to IEC 61131-9
Protocol IO-Link®
Protocol version Device V 1.1 Profile Smart sensor profile Function classes Binary data channel
(BDC) Process data variable (PDV) Identification Diagnostics Teach channel Communication mode COM2
(38.4 kBaud) SIO mode support Yes Port class A Process data width OUT 0 bytes Process data width
IN 5 bytes Process data content IN 14 bit PDV (measured value InA) 14 bit PDV (measured value InB)
2 bit BDC (measured value monitoring) Minimum cycle time 5 ms Data memory required 0.5 kilobyte
Fast and decentralised signal processing to reduce the load on the control system Remote visualisation of process values,
the display is detached Quantity detection, e.g. pressure transmitters, vacuum transmitters, flow transmitters
Object detection, e.g. inductive sensors with analogue output, distance sensors
Position detection, e.g. position sensors for pneumatic cylinders Auto difference monitoring, e.g. leak test
The signal converter can be used with the following Festo products, for example.
**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹